Boxer Pumps
Fix
Startseite

9QX Series

The 9QX is the smallest flip-top peristaltic pump available. With an elegant body design of just 40 x 62 mm (width x height) it stands just 21.5mm (depth) off a panel mount. The flip-top design allows tube loading and unloading with ultimate ease.

This series is the 3rd generation of the highly successful 9K miniature peristaltic pump from Boxer and is designed for accurate dispensing of liquids.

DC / Gear motor versions offer a range of 33 to 520 rpm with optional shaft encoder providing accurate feedback of rotor speed.

Stepper motors versions offer the versatility of finite speed / flow control with supporting drivers and optional rotor encoder.

› Flow rates from 10 μl to 200 ml/min
› Flip-top design for continuous tube
› Floating saddle for tube life > 2000 hours
› Repeatability to 1% over tube life
› 5 different tube sizes
› 3 , 4 or 6 roller configuration
› Encoder options for feedback of rpm (for DC and Stepper motor versions) 


Tubing must always be ordered separately. Flow control of the DC / Gear motor versions is available in combination with PWM Flow Controller.

Return to Peristaltic Pumps for Liquid range.


DC / Gear Motor

Economic and versatile. 5 different speeds available in 12 and 24 V.

Available to purchase online via BOX-it (see order information below).

Technical Data

Flow Data
ID Ø 0.5 mm tube 16 / 15 / 13 µl per revolution (3 / 4 / 6 Roller)
ID Ø 1.0 mm tube 55 / 50 / 42 µl per revolution (3 / 4 / 6 Roller)
ID Ø 2.0 mm tube 190 / 160 / 120 µl per revolution (3 / 4 / 6 Roller)
ID Ø 3.0 mm tube 340 / 290 / 200 µl per revolution (3 / 4 / 6 Roller)
ID Ø 3.5 mm tube 400 / 340 / 230 µl per revolution (3 / 4 / 6 Roller)
Available RPMs
12 V 116 / 315 / 520 rpm
24 V 33 / 107 / 315 / 520 rpm
Flow range (per tube ID and number of rollers)
33 rpm <link file:2279 target="_blank">⇒ 33 rpm flow table</link>
107 rpm <link file:2278 target="_blank">⇒ 107 rpm flow table</link>
116 rpm <link file:2276 target="_blank">⇒ 116 rpm flow table</link>
315 rpm <link file:2277 target="_blank">⇒ 315 rpm flow table</link>
520 rpm <link file:2275 target="_blank">⇒ 520 rpm flow table</link>
Min. values are at 50% of nominal voltage
Power Consumption 3.5 to 5.0 W
Tube Materials Pharm-a-line / Silicone / Lagoprene / ED-Plex
Max pressure 1 bar
Max vacuum -950 mbar
DC motor life >2000 hour
Weight 135 g
Optional encoder Hall sensor, 10 pulses per motor revolution
Corresponding rotor speed depends on gear ratio
All data measured with 'run-in' Pharm-a-line tubing and H2O.

Order Information

Part Number:     9010.730     12 V DC     116 RPM     3 Rollers     ⇒ BOX-it
Part Number:     9022.730     12 V DC     315 RPM     3 Rollers     ⇒ BOX-it
Part Number:     9007.730     12 V DC     520 RPM     3 Rollers     ⇒ BOX-it

Part Number:     9016.730     24 V DC       33 RPM     3 Rollers     ⇒ BOX-it
Part Number:     9012.730     24 V DC     107 RPM     3 Rollers     ⇒ BOX-it
Part Number:     9008.730     24 V DC     315 RPM     3 Rollers     ⇒ BOX-it
Part Number:     9015.730     24 V DC     520 RPM     3 Rollers     ⇒ BOX-it

 

 

 


Stepper Motor

Excellent flow / dosing control. Available in 24 V.

Available to purchase online via BOX-it (see order information below).

Technical Data

Flow Data
ID Ø 0.5 mm tube 16 / 15 / 13 µl per revolution (3 / 4 / 6 Roller)
ID Ø 1.0 mm tube 55 / 50 / 42 µl per revolution (3 / 4 / 6 Roller)
ID Ø 2.0 mm tube 190 / 160 / 120 µl per revolution (3 / 4 / 6 Roller)
ID Ø 3.0 mm tube 340 / 290 / 200 µl per revolution (3 / 4 / 6 Roller)
ID Ø 3.5 mm tube 400 / 340 / 230 µl per revolution (3 / 4 / 6 Roller)
RPM 0 to 500 rpm
Higher speeds are possible depending upon tube material, tube ID, number of rollers and driving method
Flow range (per tube ID and number of rollers) <link file:2280 target="_blank">⇒ 500 rpm flow table</link>
Power Consumption ca. 8.0 W
2 amp driver recommended, current limiter should be used for low speed operation
Tube Materials Pharm-a-line / Silicone / Lagoprene / ED-Plex
Max pressure 1 bar
Max vacuum -950 mbar
Motor life >10000 hour
Weight 245 g
Optional encoder Reed sensor, contacts close once per rotor revolution
All data measured with 'run-in' Pharm-a-line tubing and H2O.

Order Information

Part Number:     9600.730     24 V Stepper     3 Rollers     ⇒ BOX-it
Part Number:     9600.740     24 V Stepper     4 Rollers
Part Number:     9600.760     24 V Stepper     6 Rollers     ⇒ BOX-it

 

 

 

 

 

 

All data is representative for initial selection purposes. It is the responsibility of the user to determine suitability for the intended use. These products are not suitable for in-vivo applications.

Boxer Pumps
Boxer GmbH · For gas & liquids · 20 Belsize Avenue · London NW3 4AU
Phone: +44 (0)20 7794 4080 · Fax: +44 (0)20 7431 1426 · mail@boxerpumps.com · boxerpumps.com