Boxer 5100 - diaphragm pump for gases                                                                                                                                                                                                                                                                                     

Boxer 5101 - single headed gas pump

Boxer 5102 - double headed gas pump

 

· Serial or parallel head configuration for the double headed pumps

· Combined flow up to 10l/min

· Choice of DC motors—iron core or core less

· Choice of eccentrics

· High performance to size ratio

· Easy clip fixings

· Minimum pulsation thanks to integrated vibration dumpers

· No lubrication

· Maintenance free

Motor: core-less for continuous applications........................ 6V or 12V DC

Motor: iron core for intermittent operation..................................... 12V DC

Maximum current......................................................................... 600mA

Max ambient operational temperature.............................................. 40˚C

Max media temperature.................................................................. 50°C

Material wetted parts.................. Silicone & PPS (polyphenylene sulphide)

Port spigots................ Boxer 5001 Ř4.5mm OD... Boxer 5002 Ř6.0mm ID

Weight....................... Boxer 5001-115g........................ Boxer 5002-140g

 

Boxer 5102

Boxer 5101

Fixing of Boxer 5102

 

The pumps are supplied as standard with two assembly clips. The clips can be assembled onto your equipment allowing the quick installation or removal of the pump from your instrument. Use 4 c’sunk M3 screws to mount the clips onto your equipment.

 

To prevent any accidental dislocation of the pump inside the equipment during transport, please use normal cable ties to further secure the pump to the clips. The clips are formed with a special recessed area which allows to pull the cable tie between the mounting surface and the pump.

Fixing of Boxer 5101

The pumps are equipped with a removable lid. Securing the lid into your equipment allows for a quick installation or removal of the pump.

 

The lid can be secured to your equipment through two holes for  2 c’sunk M3 screws. After the lid is secured, push the Boxer 5000 pump onto the lid.

 

To prevent any accidental dislocation of the pump inside the equipment during transport, please use normal cable ties to further secure the pump onto the lid. A specially formed grove in the lid allows you to pass a cable tie between your instrument and the lid and then around the pump.